Search for Tests

Search by test name, number or alias

Back to search results

IODINE SERUM OR PLASMA

Test Number:
  • 3266
Test Alias:
Preferred Specimen:
  • Serum
Container Type:
  • No additive trace metal-free (dark blue-top) tube
Alternative Specimen:
  • Plasma collected in an EDTA trace metal-free (dark blue-top) tube
Volume:
  • 1 mL
Collection Instructions:
Transport Temperature:
  • Room Temperature • Refrigerated is acceptable
Specimen Stability:
  • Room temperature: 10 days
  • Refrigerated: 10 days
  • Frozen: Unacceptable
Methodology:
  • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
CPT Code:
  • 83789
Reject Criteria:
  • Received frozen • Anticoagulants other than EDTA
Reference Range:
  • 52-109 µg/L
Report Available:
  • 10 days

Back to search results